SILICONE KEYPAD PARTNER
Basic Information:
Process: Forming Process
Industry: Electronics
Tolerances: 0.01mm
Customized: Customized
Dimension: According to Customer’s Demand
Color: Nickel Plating, Gold Plating Metal Dome Switch
Character: Best Service + Best Price + Best Quality
Usage: Home Appliance, Electronic Equipment
Sample: Free
Transport Package: Standard Export Package or as Required
Trademark: OEM/ODM
Origin:Xiamen,china
Production Capacity: 20000 Ton/Year
Types of Products:
Quality Control:
1: Fragment Strength Test
Testing Equipment: Chatillon Model LTC Load Tester
Displacement Accuracy: 0.01 mm
Movable Range: 1 mm, 0.1 mm, 0.01 mm
Force Accuracy: 0.1gf (1 kg capacity)
Testing Head: 3.0 mm (0.12″) flat head made of Ukrainian steel, with 2.5 times strength
Height Tester Range: 0.001-600 mm, minimum unit 0.001 mm
2: Testing Procedure
Position the center of the metal shrapnel precisely in the center of the load tester’s test head. Ensure the shrapnel is aligned vertically with the test head and placed on a rigid surface. Allow for venting to maintain test result accuracy, as excess air beneath the shrapnel can impact strength and yield inaccurate results.
3: Shrapnel Life Test
Align the center of the metal shrapnel with the center of the load tester’s test head, ensuring vertical alignment and placement on a rigid surface. Provide venting to ensure test result accuracy. Conduct the life test of the shrapnel at room temperature, with a test speed range of 1-10 times per second. Utilize a 6-bit counter (1 million times), counting once per cycle.